Dahua PFM920I-6UN-CN 305m U/UTP CAT6 Network Cable – White

305 m box of white U/UTP CAT6 network cable with oxygen-free copper conductors. Carries Power over Ethernet and has a flame-retardant CPR Eca jacket.

SKU: PFM920I-6UN-CN Category:
Product Specifications
Conductor
Material Oxygen free copper (99.97% purity)
Conductor Structure 0.53 mm ± 0.02 mm (0.0209" ± 0.0008")
American Wire Gauge 24AWG
Insulation
Insulating Material HDPE
Min. Average Thickness 0.21 mm (0.0083")
Insulation Diameter 0.95 mm ± 0.1 mm (0.0374" ± 0.0039")
Insulation Color 8 cores, Blue, white/blue; Orange, white/orange; Green, white/green; Brown, white/brown
Rip Cord
Material Polyester
Specification 500D
Separator
Material PE
Specification Translucent 4.5 mm × 0.4 mm (0.18" × 0.0157")
Sheath
Min. Average Thickness 0.5 mm (0.02")
Sheath Material PVC
Sheath Diameter 5.8 mm ± 0.30 mm (0.23" ± 0.0118")
Sheath Color White
Electrical
Max. DC Resistance of a Single Conductor 9.0 Ω@100 m (328.08 ft)
Min. Insulation Resistance 5000 MΩ·km
Max. DC Resistance Unbalance 2% (pair intra), 4% (pairs inter)
Dielectric Strength No breakdown with 1kV DC for 1 min
Transmission
Characteristic Impedance 100 Ω ± 15 Ω
Near-end Crosstalk ≥39.3 dB/100 m@250 MHz
Max. Attenuation 34.8 dB/100 m@250 MH
Return Loss ≥17.3 dB/100 m@250 MHz
Mechanical
Tensile Strength Sheath≥13.5 MPa, insulation≥16 Mpa
Elongation at Break Sheath≥150%, insulation≥300%
Installation Bending Radius >8 times of outer cable diameter
Conductor Elongation at Break ≥10%
Environmental
Shrinkage of Insulation ≤5%
Color Migration Resistance of Insulation No migration
Sheath Tensile Strength and Elongation at Break after Aging ≥12.5 MPa, ≥125%
Low Temperature Bending Test No cracking after the test
Heat Shock Test No cracking after the test
Operating Temperature –20 °C to +60 °C (–4 °F to +140 °F)
Installation Temperature 0 °C to +50 °C (+32 °F to +122 °F)
Storage Temperature –10 °C to +40 °C (+14 °F to +104 °F)
Storage Humidity <60% (RH)
Security
Vertical Flame Test Comply with IEC 60332-1-2
Packaging
Cable Length 305.0 m± 2 m (1,000.66 ft ± 6.56 ft)
Packaging Method 305 m (1,000 ft) a carton, one carton with 2 inner cartons
Packaging Dimensions 403 mm × 401 mm × 210 mm (15.87" × 15.79" × 8.27") (L × W × H)
Transport Package Dimensions 455 mm × 435mm × 436mm (17.91" × 17.13" × 17.17") (L × W × H)
Net Weight 11.0 kg ± 0.5 kg (24.25 lb ± 1.10 lb)
Gross Weight 12.3 kg ± 0.5 kg (27.12 lb ± 1.10 lb)
Compliance Standard
Compliance Standard Q/DXJ 067-2024, EN50575
Certifications
Certifications CPR Eca
Flame-retardant Standard
Compliance Standard EN50575
Product Datasheet

Download datasheet (PDF)

Source: official manufacturer datasheet.